10 x13 - motor connection (power - only ax5140) – BECKHOFF AX5000 1,5 A - 40 A User Manual

Page 26

Advertising
background image

4 Product description

BECKHOFF

Drive Technology

26

Version : 4.6

AX5000

4.7.9

X13 (channel A) , X23 (channel B) - motor connection (power)

(AX5101 - AX5125 und AX520x)

Terminal point

Connection

U

Motor connection U

V+

Motor connection V

W

Motor connection W

PE

Protective conductor

Shroud

Screen

4.7.10 X13 - motor connection (power - only AX5140)

Terminal point

Connection

U

Motor connection U

V+

Motor connection V

W

Motor connection W

PE

Protective conductor

Shroud

Screen

Attention

Grounding shield!
The grounding shield of the motor is connected via the shield plate in the

motor connector. Please tighten the knurled screws of the motor connector

with a screwdriver. It is possible that some feedback problems may caused

due to a poor shield connection of the motor.

4.7.11 X14 (channel A), X24 (channel B)-motor brake, thermal contact, OCT

AX5000-xxxx-0000 (Hardware 1)

Terminal point

Connection

Output current

T-

Temp. -

*

T+

Temp. +

*

PE

Signal pair screen

B-

Brake GND

B+

Brake (U

p

) +

1.5 A max.

*) Switch, KTY 83-1xx or KTY 84-1xx

Advertising