7 overview of connectors/terminal points, 1 x01 - wide voltage input, 2 x02 - dc link (ax5101 - ax5125 und ax520x) – BECKHOFF AX5000 1,5 A - 40 A User Manual

Page 23: 3 x02 - dc link (only ax5140), 4 x03 - 24 vdc supply

Advertising
background image

BECKHOFF

Drive Technology

4 Product description

AX5000

Version : 4.6

23

4.7

Overview of connectors/terminal points

4.7.1

X01 - wide voltage input

Terminal point

Connection

Tightening

torque

3-phase

1-phase

L1

Phase L1

Phase L1

0,5 -0,6 Nm

L2

Phase L2

not used

L3/ N

Phase L3

Neutral conductor

PE

Protective conductor

4.7.2

X02 - DC link (AX5101 - AX5125 und AX520x)

Terminal point

Connection

Tightening

torque

DC+

DC link +

external brake resistor

and drive system

0,5 -0,6 Nm

DC –

DC link –

4.7.3

X02 - DC link (Only AX5140)

Terminal point

Connection

Tightening

torque

DC+

DC link +

only for drive system

1,2 -1,5 Nm

DC –

DC link –

WARNING

Serious risk of injury through high electrical voltage!
890 V DC voltage at the DC link terminals. Dangerous voltage may be

present for 5 minutes after the device is switched off.

Remove the connector only if you want to build a drive system with a AX-

Bridge.

Remove the white hexagon plugs only if you wire the terminal points again.

4.7.4

X03 - 24 V

DC

supply

Terminal

point

Connection

Current

consumption

Tightening

torque

U

p

+

24 V

DC -0/+25%

- periphery

(e.g. separate braking

voltage)

Depending on the

connected consumers

(see X06 and X14,X24)

0,5 – 0,6 Nm

U

s

+

24 V

DC ±25%

- system

supply (depending on

rated current)

-12 A = 0.4 A – 0.8 A

18 A - 25A = 1,1 A

40 A = 1,6 A

GND

GND

Advertising