Carbon filters, Electronic air cleaner – Belshaw Adamatic INSIDER Ventless Donut System User Manual

Page 40

Advertising
background image

Belshaw Bros., Inc.

• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425

14 MN-1853EN

Insider

TS

2. Attach a pipe wrench to a convenient

location on the jackshaft or use a 1/2” open-
end wrench on the end of the drive shaft.

3. Rotate the jackshaft in a clockwise direction

until the other coupler post is in position and
install the fusible link onto the post.

4. Slowly reduce pressure on the pipe wrench

until slack is taken up by the fusible link.

WARNING

The damper must be armed. It is shipped

with the safety pin installed.

CAUTION

Do not put hands or fingers into the fire

damper. It is spring-loaded and bodily

harm could result.

Carbon Filters

The carbon filters are 1-3/4 inches by 11-1/2
inches by 19-1/2 inches. The INSIDER requires
the use of two (2) filters. The carbon filters
should be replaced every six (6) months.

Electronic Air Cleaner

Maintenance and Washing
When to Wash:
Periodically the dirt collected by your unit must
be removed. The frequency of washing will
depend on the amount of dirt present in the air in
you locality.

The washing frequency best suited for you unit
can be determined by examining the dirt
collected components at three (3) week intervals.
As the dirt begins to collect, you will notice a
light film, then a very definite collection will be
evident at a later examination. When there is a
noticeable build-up of dirt, it is time to wash.
In most areas the collecting cell should be
washed about every twelve (12) weeks.
Note: Dirt build-up on the ionizing-collecting

cell should not be confused with dirt
stains. Dirt stains are normal and do not
affect efficiency.

Steps for Washing:
1.

Switch control switch “OFF”.

2.

Remove pre-filter and cell.

3.

Place components in automatic dishwasher,
stationary tub, shower stall or over floor
drain. Use hot soapy water and rinse
thoroughly. As an aid to drying, rinse with
clear, hot water. Allow components to dry
thoroughly.

Note: Ionized wires are easily broken. Handle

the cells with care.

4.

Replace pre-filter and cell.

5.

Close cell access door.

6.

Switch control switch to “ON”.0

If arcing noise occurs due to wet cells, turn
switch off and allow more drying time.
If there are any problems, refer to the service
checklist.

Advertising