3 electronic air cleaner – troublechart, 4 electronic air cleaner symptoms and corrections – Belshaw Adamatic INSIDER Ventless Donut System User Manual

Page 44

Advertising
background image

Belshaw Bros., Inc.

• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425

18 MN-1853EN

Insider

TS

3 ELECTRONIC AIR CLEANER – TROUBLECHART

Condition

or

Symptom

Trouble

Description

Probable

Location

Possible

Cause

Correction

Power On/Off
Light (Amber) out

Open Primary
Circuit

Primary Wiring




On/Off Switch

No power from
service
connection to
power supply.

Loose wiring
Defective wiring

Obtain power




Repair
Replace

Cracking Noise

Objectionable
Noise

Cell Loose

Ionizing

wire
Dirty cell
Damaged (bent)
plates
Damaged (bent)
ionizer

Replace

Wash
Straighten or
replace
Straighten or
replace

Loud Hissing
Noise

Same Cell

Hi-Voltage
Connection

Dirty Cell
Loose Hi-Voltage
Connection
Insufficient
ground

Wash
Correct

Correct

Radio and/or TV
interference

Same Cell

Hi-Voltage
Connection

Improper ground
Loose Hi-Voltage
Connection

Correct
Correct

Odor of Ozone

Same

See Page 25

4 Electronic Air Cleaner
Symptoms and Corrections

1. Arcing Noise
When an arcing noise is noted, it is usually
located in the DC high voltage circuit. The
ionizing-collecting cell is part of this circuit and
normally the trouble will be found to be in the
cell. The noise is caused by high voltage arcing
to ground.
An occasional arcing noise is normal and
inherent in all precipitators. These occasional
arcs are caused by large particles of dirt in the air
such as a cigarette ash, insect, etc. Constant or
repeated intermittent arcing should be checked.

Check for:
Loose ionizing wire(s) – repair or replace.
Excessively dirty cell components – clean.
Damaged (bent) plates of ionizer – straighten or
replace.
Defective or loose high voltage lead or contact
assembly – repair, or replace.
Cracked insulator – replace.
Improper ground – check ground and correct if
necessary.