Datalogic Scanning FALCON 4400 SERIES User Manual

Page 100

Advertising
background image

Programming Parameters

E-4

Falcon

®

4400 Series with Windows

Mobile

®

Send Start/
Stop

Instructs the decoder to transmit
the decoded start and stop charac-
ters of Codabar labels. The start
and stop characters will both be
translated as A, B, C, or D.

0
3
0
5

On or

Off

Off

On

Off

9

9

Convert to
CLSI

Restricts the Codabar decoder to
only read labels that conforms to

CLSI

specifications. Label length

must be 14, and the data is split
into fields of 1, 4, 5, and 4 charac-
ters separated by spaces.

0
3
0
6

On or

Off

Off

Off

Off

9

Allow Wide
Interchar-
acter Gaps

Allows wide gaps to appear
between characters in a label.

0
3
0
7

On or

Off

Off

On

On

9

Minimum
Label
Length

Set the minimum label length to be
less than or equal to maximum
label length.

0
3
2
0

01 - 50

01

01

04

9

9

Maximum
Label
Length

This feature specifies the maximum
allowable length of a Codabar label.
The length includes check and data
characters. Maximum Label Length
should be greater than or equal to
Minimum Label Length.

0
3
2
1

01 - 50

01

50

20

9

9

Read Veri-
fication

Sets the number of times a label
must be read before it is transmit-
ted.

0
3
2
2

01 - 04

01

02

01

9

Code Parameter/ Description

I.

D.

#

Accep-

table

Input

Defaults

Scanner Type

Min

Max

Fac-

tory

Laser/

Linear

Imager

2D

Imag

er

Advertising