Trioptic, 9trioptic – Datalogic Scanning FALCON 4400 SERIES User Manual

Page 116

Advertising
background image

Programming Parameters

E-20

Falcon

®

4400 Series with Windows

Mobile

®

Maximum
Label
Length

This feature specifies the maximum
allowable length of a Standard 2 of
5 label. The length includes check
and data characters. Maximum
Label Length should be greater
than or equal to Minimum Label
Length.

0
2
2
1

01 - 50

01

50

10

9

9

Read Veri-
fication

Sets the number of times a label
must be read before it is transmit-
ted.

0
2
2
2

01 - 04

01

02

01

9

User ID

Specifies the symbology identifier
(if any) that is sent when parameter
Send Code ID (Index 0025) is set to
3.

ASCII

code zero (null) is used

to indicate that an identifier is not to
be sent for the symbology.

0
2
2
3

Any

single
ASCII

charac-

ter

(00 =

Off)

'F'

'F'

'F'

9

9

Trioptic

Enter 1 for On

and 0 for Off.

Enable

Enables/disables the Trioptic sym-
bology.

0
1
0
8

On or

Off

Off

On

Off

9

9

Enable
Aggres-
sive
Decoding

Enables more aggressive decoding
algorithms to be used in order to
scan hard to read labels.

0
1
0
9

On or

Off

Off

On

Off

9

Read Veri-
fication

Sets the number of times a label
must be read before it is transmit-
ted.

0
1
2
4

01 - 04

01

02

01

9

Code Parameter/ Description

I.

D.

#

Accep-

table

Input

Defaults

Scanner Type

Min

Max

Fac-

tory

Laser/

Linear

Imager

2D

Imag

er

Advertising