Imaging controls – Datalogic Scanning FALCON 4400 SERIES User Manual

Page 127

Advertising
background image

Bar Code Parameters

Product Reference Guide

E-31

Table E-4. Imaging Controls

QR Code
Maximum

This feature specifies the maxi-
mum allowable length of a label.
The length includes check and
data characters, if applicable.
Maximum Label Length should be
greater than or equal to Minimum
Label Length.

0

B

2
9

1 - 3500

1

3500

3500

9

QR Code
User ID

Specifies the symbology identifier
(if any) that is sent when parame-
ter Send Code ID (Index 0025) is
set to 3.

ASCII

code zero (null) is

used to indicate that an identifier is
not to be sent for the symbology.

0

B

2

B

Any sin-

gle

ASCII

charac-

ter (00 =

Off)

‘c’

‘c’

‘c’

9

Code Parameter/ Description

I.

D.

#

Accep-

table

Input

Defaults

Min

Max

Factory

Imaging Controls

Enter 1 for On and 0 for Off.

Imager Illu-
minate
Enable

Instructs the PDT to illuminate the scanning
area (independent of any targeting beam)
when using an imager.

0
0
0
8

On or

Off

On

On

On

Imager Aim
Mode

Toggles between two different operating
modes for the targeting beam:
Concurrent (Off): The targeting beam is
turned on at the same time as an enabled
illumination beam.
Interlaced (On): Toggles the aimer and illu-
mination beam.

0
0
0
9

On or

Off

On

On

On

Code Parameter/ Description

I.

D.

#

Accept

able

Input

Defaults

Scanner Type

Min

Max

Fac-

tory

Laser/

Linear

Imager

2D

Imag

er

Advertising