Datalogic Scanning FALCON 4400 SERIES User Manual

Page 110

Advertising
background image

Programming Parameters

E-14

Falcon

®

4400 Series with Windows

Mobile

®

Send
Checksum

Instructs the terminal to include the
checksum in the label transmission.

0
2
0

B

On or

Off

Off

Off

Off

9

Minimum
Label
Length

Set the minimum label length to be
less than or equal to maximum
label length.

0
2
2
4

01 - 50

01

01

06

9

9

Maximum
Label
Length

This feature specifies the maximum
allowable length of a Matrix 2 of 5
label. The length includes check
and data characters. Maximum
Label Length should be greater
than or equal to Minimum Label
Length.

0
2
2
5

01 - 50

01

50

10

9

9

Read Veri-
fication

Sets the number of times a label
must be read before it is transmit-
ted.

0
2
2
6

01 - 04

01

02

01

9

User ID

Specifies the symbology identifier
(if any) that is sent by the decoder
when parameter Send Code ID
(Index 0025) is set to 3.

ASCII

code zero (null) is used to indicate
that an identifier is not to be sent for
the symbology.

0
2
2
7

Any

single
ASCII

charac-

ter

(00 =

Off)

'D'

'D'

'D'

9

9

Code Parameter/ Description

I.

D.

#

Accep-

table

Input

Defaults

Scanner Type

Min

Max

Fac-

tory

Laser/

Linear

Imager

2D

Imag

er

Advertising