Datalogic Scanning FALCON 4400 SERIES User Manual

Page 131

Advertising
background image

Bar Code Parameters

Product Reference Guide

E-35

Spotting Beam
Timeout

Sets the duration of the spotting beam
before it automatically turns off.

0
0
2
3

00 = 0.25 sec.

01 = 0.5 sec.
02 = 1.0 sec.
03 = 1.5 sec.
04 = 2.0 sec.

01

01

01

Release Scan
Timeout

Sets the duration of the scan before it
turns off.

0
0
2
4

1-10

02

02

02

Number of
Good-Read
Beeps

Determines the number of beeps for a
good read indicator.

0
0
2
0

01 - 04

01

01

01

Good-Read
Beep Tone

Adjusts the pitch of the beeper frequency.

0
0
2
1

00 - 07

(00 = Lowest;
07 = Highest)

00

00

00

Good-Read
Beep Duration

Determines the duration of a good read
beep.

0
0
2
2

00 = 0.07 sec.
01 = 0.13 sec.
02 = 0.18 sec.
03 = 0.36 sec.

00

00

00

Send Symbol-
ogy Identifiers

Specifies the symbology identifier (if any)
that is sent by the decoder when parame-
ter Send Code ID (Index 0025) is set to 3.

ASCII

code zero (null) used to indicate

an identifier not to be sent for the symbol-
ogy.

0
0
2
5

00 = Off

01 = DLM

IDs*

02 = AIM IDs

03 = User IDs

00

01

00

Label Prefix

Indicates a label prefix.

0
0
2
6

Any single

ASCII charac-

ter

(00 = Off)

No

ne

Non

e

None

Code Parameter/ Description

I.

D.

#

Acceptable

Input

Defaults

Min

Max

Factory

Advertising