Electromagnetic Compatibility Information

Guidance and manufacture’s declaration – electromagnetic emissions – for all EQUIPMENT and SYSTEMS

Guidance and manufacture’s declaration – electromagnetic emission
The BM49 blood pressure monitor is intended for use in the electromagnetic environment specified below. The customer

of the user of the BM49 blood pressure monitor should assure that it is used in such and environment.
Emission test

Compliance Electromagnetic environment – guidance

RF emissions CISPR 11 Group 1

The BM49 blood pressure monitor uses RF energy only for its internal function.

Therefore, its RF emissions are very low and are not likely to cause any interfe-

rence in nearby electronic equipment.

RF emission CISPR 11

Class B

The BM49 blood pressure monitor is suitable for use in all establishments, inclu-

ding domestic establishments and those directly connected to the public low-vol-

tage power supply network that supplies buildings used for domestic purposes.

Guidance and manufacture’s declaration – electromagnetic immunity – for all EQUIPMENT and SYSTEMS

Guidance and manufacture’s declaration – electromagnetic immunity
The BM49 blood pressure monitor is intended for use in the electromagnetic environment specified below. The customer

or the user of the BM49 blood pressure monitor should assure that it is used in such an environment.
Immunity test

IEC 60601

test level

Compliance

level

Electromagnetic environment – guidance

Electrostatic discharge (ESD)

IEC 61000-4-2

± 6 kV contact

± 8 kV air

± 6 kV contact

± 8 kV air

Floors should be wood, concrete or ceramic tile. If floor

are covered with synthetic material, the relative humi-

dity should be at least 30%.

Power frequency (50Hz)

magnetic field

IEC 61000-4-8

3 A/m

3 A/m

Power frequency magnetic fields should be at levels

characteristic of a typical location in a typical commer-

cial or hospital environment.

Guidance and manufacture’s declaration – electromagnetic immunity – for EQUIPMENT and SYSTEMS that are not

LIFE-SUPPORTING

Guidance and manufacture’s declaration – electromagnetic immunity
The BM49 blood pressure monitor is intended for use in the electromagnetic environment specified below. The customer

or the user of the BM49 blood pressure monitor should assure that it is used in such an environment.
Immunity test IEC 60601

test level

Compliance

level

Electromagnetic environment – guidance

Conducted RF

IEC 61000-4-6

Radiated RF

IEC 61000-4-3

3 V

rms

150 kHz to

80 MHz

3 V/m

80 MHz to

2.5 GHz

3 V

rms

3 V/m

Portable and mobile RF communications equipment should be used no clo-

ser to any part of the BM49 blood pressure monitor, including cables, than

the recommended separation distance calculated from the equation appli-

cable to the frequency of the transmitter.
Recommended separation distance:
d =

d =

80 MHz to 800 MHz

d =

800 MHz to 2.5 GHz

Where P is the maximum output power rating of the transmitter in watts (W)

according to the transmitter manufacturer and d is the recommended sepa-

ration distance in metres (m).
Field strengths from fixed RF transmitters, as determined by an electroma-

gnetic site survey,

a

should be less than the compliance level in each fre-

quency range.

b

Interference may occur in the vicinity of

equipment marked with the following symbol: