Current considerations – Cloud Electronics PM12 User Manual

Page 15

Advertising
background image

PM4/8/12/16 Installation and User Guide v2.2

15

recommended cable length between the Cloud host mixer and the “last”

PM should not exceed 50 m. If longer cable lengths are required, then an

external PSU should be connected to the PM.

2.

Via the Analogue Port. The PM’s analogue interface allows for DC power.

The ‘+V’ and ‘0V’ terminals of the internal port connector should be wired

to the ‘+V’ and ‘0V’ pins respectively of the access connector at the Cloud

host mixer. This method of powering requires an additional core in

the access cable (the ‘0V’ connection will need to be made in any case for

the zone selection to function). Only one microphone may be powered

from the mixer in this way.

The wiring diagram on page 19 illustrates this

connection.

Current considerations

The table below gives the current required by the various PM models:

PM Model

Required Current

PM4

72 mA

PM8

83 mA

PM12

95 mA

PM16

107 mA

The following table shows spare DC current available from various Cloud host
mixers, etc., for powering additional items:

Host

Available Current

DCM-1

650 mA

Z4ii

120 mA

Z8ii

190 mA

CX163

Use ext. PSU

CX263

Use ext. PSU

36/50

Use ext. PSU

46/50

80 mA

These figures apply to the host units without any active options installed, such as

internal Bose

®

EQ cards or remote plates. These options all consume power, so the

available current may be insufficient to power the PM. In such cases, an external PSU
must be used.