Jumper and default settings summary, Technical specifications – Cloud Electronics PM12 User Manual

Page 33

Advertising
background image

PM4/8/12/16 Installation and User Guide v2.2

33

Jumper and default settings summary

Jumper

Purpose

Default

J1

Chime Select; +1

ON

J2

Chime Select; +2

OFF

J3

Chime Select; +4

OFF

J4

Digital Paging Interface termination

ON

J5

Chime On/Off

ON

J6

Internal Chime On/Off

ON

J7

NVM Reset

OFF

J8

High Priority

OFF

J9

Lock Groups

OFF

J10

Auto-reset zone selection

ON

J11

Zone Offset; +1

OFF

J12

Zone Offset; +2

OFF

J13

Zone Offset; +4

OFF

J14

Zone Offset; +8

OFF

Technical Specifications

Microphone

Capsule Type

Condenser

Polar Pattern

Cardioid

Zones

Number of Zones

4, 8, 12, 16

Chime

Number of Chimes

4, with Internal Speaker

Interface

Digital

Cloud Digital Paging Interface (RJ45)

Analogue

Zone Access Output (Short to Ground)
Audio Output

Power input

9 - 17 VAC, 12 - 24 VDC

Current

consumption

72 mA (4 zone), 83 mA (8 zone), 95 mA (12 zone), 107 mA (16 zone)

Dimensions

(mm)

PM

245 wide x 65 high (less gooseneck mic) x 170 deep

Gooseneck length

300 (standard); 140 (alternative Part No. MI100166)

Net Weight (kg)

1.2

Advertising
This manual is related to the following products: