PM4/8/12/16 Installation and User Guide v2.2

29

Using the analogue interface with multiple PMs

The “last” mixer in the chain – that connected to the host mixer – may be connected
to the host via the analogue interface instead of the Digital Paging Interface, if the
host mixer is not equipped with the digital interface. Connect the PM in the same

way as if it was the only PM in the system, using separate audio and control cables.

See page 18

for full details.

Communication between PMs will be via the digital interface, and between the last
PM (effectively the whole network) and the host will be via the analogue interface.

Consideration needs to be given to any zone offsets applied to the various PMs on

the network. For example, in a 12-zone system with three PM4s configured to page
Zones 1 to 4, 5 to 8 and 9 to 12 respectively, analogue port terminals Z1 to Z12

inclusive will need to be wired to the host mixers for correct operation.

Priorities

A potential problem exists in paging systems employing multiple paging microphones

in the form of announcement “collisions”. A collision will occur if an announcement
is attempted from one paging microphone while another is already in progress. As

any one microphone will probably only be in earshot of one zone’s loudspeakers,
it is possible for a microphone to be paging a zone and operators at other paging

(with Digital Paging Interface)

Mixer

MIC INPUT

PAGING ACCESS

Mixer

+12V

Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8

0V

LF

HF

GAIN (dB)

50

1

2

3

10

+

-

-

+

(with Analogue Paging Interface)

IN

OUT

OUT

Termination OFF

CAT-5

CAT-5

CAT-5

CAT-5

CAT-5
(INCLUDING DC POWER FROM MIXER)

(INCLUDING DC POWER FROM MIXER)

Termination

OFF

Termination ON

IN

OUT

Termination

ON

IN

OUT

AUDIO OUT

ZONE ACCESS CONTROL

Termination

OFF

IN

OUT

Termination

ON

PSU

PSU

PSU

PSU

CDPM

GAIN (dB)

IN

THRU

-10

+10

Termination ON

T