Comtech EF Data SLM-5650A User Manual

Page 368

Advertising
background image

SLM-5650A Satellite Modem

Revision 8

Appendix C

MN-SLM5650A

C–16

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Rx BERT State BRX=

1 byte, value of 0

or 1

Command or Query.
Rx BERT State, where:

0=Off

1=On

Example: BRX=1 (Rx BERT On)

BRX=

BRX?

BRX*

BRX#

BRX?

BRX=x

(see Description

of Arguments)

Rx Eb/No

N/A

4 bytes

Query only.
Returns the value of Eb/No, between 0 and 20 dB, resolution = 0.1 dB.
Returns 99.9 if demod is unlocked.
Example: EBN=12.3 (selects Eb/No = 12.3 dB)

For values greater than 20.0 dB, the reply will be: EBN=+020

N/A

EBN?

EBN=xxxx

(see Description

of Arguments)

Rx BERT Errors N/A

7 bytes

Query only.
Read the total number of Bit Errors.
Example: ERR=9999999

N/A

ERR?

N/A

Rx Buffer

Programming

Mode

RBM=

1 byte, value of 0

or 1

Command or Query.
Rx Buffer Programming Mode, where:

0 = Buffer Size is programmed in Bits.

1 = Buffer Size is programmed in milliseconds.

Note: Commands as well as queries are not allowed when either the GigaBit

Ethernet or NP card has been selected as the current interface type.
Example: RBM=0

RBM=

RBM?

RBM*

RBM#

RBM?

RBM=x

(see Description

of Arguments)

Rx BPSK Data

Ordering

RBO=

1 byte, value of 0

or 1

Command or Query.
Invert Receive BPSK Data Ordering in the form x, where:

0=Standard

1=Non-Standard
Example: RBO=1 (selects Inverted BPSK Ordering)

RBO =

RBO?

RBO*

RBO#

RBO?

RBO=x

(see Description

of Arguments)

Rx Buffer Size

RBS=

8 bytes

Command or Query.
Rx Buffer Size (in either bits or milliseconds, see RBM command), where:

xxxxxxxx=Rx Buffer Size

Note: Commands as well as queries are not allowed when either the GigaBit

Ethernet or NP card has been selected as the current interface type.
Example: RBS=00000512

RBS=

RBS?

RBS*

RBS#

RBS?

RBS=xxxxxxxx

(see Description

of Arguments)

ReCenter Buffer RCB=

None

Command only.
Forces the software to recenter the receive Plesiochronous / Doppler buffer.
Note: This command is not allowed when either the GigaBit Ethernet or NP card has

been selected as the current interface type.
Example: RCB= (ReCenter buffer)

RCB=

RCB?

RCB*

RCB#

N/A

N/A