Comtech EF Data SLM-5650A User Manual
Page 377

SLM-5650A Satellite Modem
Revision 8
Appendix C
MN-SLM5650A
C–25
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
IP Address
IPA=
18 bytes,
numerical
Command or Query.
Used to set the IP address and network prefix for the 10/100 BaseTx Ethernet
management port, in the format xxx.xxx.xxx.xxx.yy, where:
xxx.xxx.xxx.xxx is the IP address, and
yy is the network prefix (0-31)
Example: 010.006.030.001.24
IPA=
IPA?
IPA*
IPA#
IPA?
IPA=
xx.xxx.xxx.xxx.yy
(see Description
of Arguments)
Initialize
Statistics
Pointer
ISP=
None
Command only.
Resets internal pointer to allow RNS? queries to start at the beginning of the stored
statistics log.
ISP=
ISP#
N/A
N/A
LoopBack Test
Modes
LOP=
1 byte, value of 0
thru 2
Command or Query.
Loopback Test Modes, where:
0=Normal Mode (no test)
1=IF Loopback
2=I/O Loopback #1
Example: LOP=1 (IF Loopback)
LOP=
LOP?
LOP*
LOP#
LOP?
LOP=x
(see Description
of Arguments)
Local/Remote
Status
LRS=
1 byte, value of
0, 1, or 3
Command or Query.
Local/Remote status, where:
0=Local
1=Serial Remote Control
3=Serial + Ethernet Remote Control
Example: LRS=1 (selects Serial Remote)
LRS=
LRS?
LRS*
LRS#
LRS?
LRS=x
(see Description
of Arguments)
Modem
Reference
Clock
MRC=
1 byte, value of 0
thru 3
Command or Query.
Modem Reference Clock (for Frequency Accuracy), where:
0=Internal
1=External 1 MHz
2=External 5 MHz
3=External 10 MHz
MRC=
MRC?
MRC*
MRC#
MRC?
MRC=x
(see Description
of Arguments)
Modem Alarm
Mask
MSK=
6 bytes
Command or Query.
Alarm mask conditions, in the form abcdef, where:
a=spare ( must be set to 0 )
b=spare ( must be set to 0 )
c=spare ( must be set to 0 )
d=spare ( must be set to 0 )
e=Demod Faults (0 = unmasked, 1 = masked )
f=Eb/No Threshold Alarm (0 = unmasked, 1 = masked)
Example: MSK=000001
MSK=
MSK?
MSK*
MSK#
MSK?
MSK=abcdef
(see Description
of Arguments)