Config: tx, Overhead, Frequency – Comtech EF Data SLM-5650A User Manual

Page 93

Advertising
background image

SLM-5650A Satellite Modem

Revision 8

Front Panel Operation

MN-SLM5650A

5–11

CONFIG: Tx

Overhead

Tx: Overhead:None Rate: N/A

RS-CW:N/A

Depth:N/A (E)

First, use the  arrow keys to select Overhead, Rate, RS-CW, and Depth, and then press

[ENT]. Then, use the  arrow keys to scroll through the available settings. Press [ENT] once

again when done.

Option

Setting

Overhead

IESS-308, IESS-309 are standard; AUPC is optional.

Rate

96 kbps (IESS-308); 1/15 (IESS-309 or AUPC); N/A (None).

RS-CW

Reed-Solomon Code Word, N/K: 126/112, 194/178, 208/192, 219/201, 220/200, 225/205.

Depth

Interleaving depth: 4, 8 or 16.

Some selections will only be visible if the modem is set to a compatible mode, or

if an option is installed or enabled.

CONFIG: Tx

Frequency

Tx Frequency: 1955.0000 MHz

Spectrum: Normal (E)

First, use the  arrow keys to select Tx Frequency or Spectrum, and then press [ENT].

Use Method 1 or Method 2 to enter the desired Tx Frequency:

Method

Procedure

1

Use the number keypad and enter the desired frequency. Press [ENT] when done.

2

Select the digit to be edited using thearrow keys, and then change the value of that digit by

using the  arrow keys. Press [ENT] when done. Note the following:
For 70/140 MHz:
Valid range is 52

88, 104

176 MHz (in 100 Hz steps).

For L-Band: Valid range is 950

2000 MHz (in 100 Hz steps).

When entering an IF frequency, the M&C will check the occupied bandwidth

calculated from the data rate, modulation type, code rate and overhead and will

not allow an IF frequency to be entered if the occupied bandwidth falls outside of

the minimum or maximum IF frequencies.

Select Spectrum to counteract frequency converters that invert the spectrum. Use the  arrow

keys to select Normal or Invert, and then press [ENT] when done.

Advertising