Comtech EF Data SLM-5650A User Manual
Page 384

SLM-5650A Satellite Modem
Revision 8
Appendix C
MN-SLM5650A
C–32
C.6.6 Automatic Uplink Power Control (AUPC) Commands / Queries
The instruction codes that follow are valid only when the SLM-5650A Satellite Modem type has been set to AUPC.
Note: Always wait three (3) seconds between consecutive remote modem command/query polls. If Local AUPC is not enabled, queries will return
the last known condition. A request for status from the remote modem will then be transmitted, ensuring that the next query will return current status.
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
ASYNC ESC
Type
ACT=
1 byte
Command or Query.
ASYNC ESC Type, where:
0=RS-232
1=RS-485 2-Wire
2=RS-485 4-Wire
Example: ACT=0 (sets the ASYNC ESC to RS-232)
ACT=
ACT?
ACT*
ACT#
ACT?
ACT=x
(see Description
of Arguments)
AUPC Eb/N0
Target Set Point
AET=
4 bytes
Command or Query.
AUPC Eb/N0 Target, where:
xx.x = AUPC Eb/N0 Target, 3.2 to 16.0 dB.
Example: AET=13.4
AET=
AET?
AET*
AET#
AET?
AET=xx.x
(see Description
of Arguments)
AUPC Minimum
Power Level
AMN=
5 bytes
Command or Query.
Minimum Tx Output power level, where:
s=sign ( + / – )
xx.x = Tx Output power level, +10.0 and –40.0 dBm.
Example: AMN = –13.4
AMN=
AMN?
AMN*
AMN#
AMN?
AMN=sxx.x
(see Description
of Arguments)
AUPC
Maximum
Tracking Rate
AMT=
3 bytes
Command or Query.
AUPC Maximum Tracking Rate, where:
x.x = Maximum Tracking Rate, 0.5 to 6.0 dBm/minute in increments of .5.
Example: AMT=0.5
AMT=
AMT?
AMT*
AMT#
AMT?
AMT=x.x
(see Description
of Arguments)
AUPC
Maximum
Power Level
AMX=
5 bytes
Command or Query.
Maximum Tx Output power level, where:
s=sign ( + / - )
xx.x = Tx Output power level, +10.0 and –40.0 dBm.
Example: AMX=-13.4
AMX=
AMX?
AMX*
AMX#
AMX?
AMX=sxx.x
(see Description
of Arguments)
AUPC Nominal
Power Level
ANP=
5 bytes
Command or Query.
Nominal Tx Output power level, where:
s=sign ( + / - )
xx.x = Tx Output power level, +10.0 and –40.0 dBm.
Example: ANP=-13.4
ANP=
ANP?
ANP*
ANP#
ANP?
ANP=sxx.x
(see Description
of Arguments)