C–32

C.6.6 Automatic Uplink Power Control (AUPC) Commands / Queries

The instruction codes that follow are valid only when the SLM-5650A Satellite Modem type has been set to AUPC.

Note: Always wait three (3) seconds between consecutive remote modem command/query polls. If Local AUPC is not enabled, queries will return

the last known condition. A request for status from the remote modem will then be transmitted, ensuring that the next query will return current status.

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

ASYNC ESC

Type

ACT=

1 byte

Command or Query.
ASYNC ESC Type, where:

0=RS-232

1=RS-485 2-Wire

2=RS-485 4-Wire
Example: ACT=0 (sets the ASYNC ESC to RS-232)

ACT=

ACT?

ACT*

ACT#

ACT?

ACT=x

(see Description

of Arguments)

AUPC Eb/N0

Target Set Point

AET=

4 bytes

Command or Query.
AUPC Eb/N0 Target, where:

xx.x = AUPC Eb/N0 Target, 3.2 to 16.0 dB.

Example: AET=13.4

AET=

AET?

AET*

AET#

AET?

AET=xx.x

(see Description

of Arguments)

AUPC Minimum

Power Level

AMN=

5 bytes

Command or Query.
Minimum Tx Output power level, where:

s=sign ( + / – )

xx.x = Tx Output power level, +10.0 and –40.0 dBm.

Example: AMN = –13.4

AMN=

AMN?

AMN*

AMN#

AMN?

AMN=sxx.x

(see Description

of Arguments)

AUPC

Maximum

Tracking Rate

AMT=

3 bytes

Command or Query.
AUPC Maximum Tracking Rate, where:

x.x = Maximum Tracking Rate, 0.5 to 6.0 dBm/minute in increments of .5.
Example: AMT=0.5

AMT=

AMT?

AMT*

AMT#

AMT?

AMT=x.x

(see Description

of Arguments)

AUPC

Maximum

Power Level

AMX=

5 bytes

Command or Query.
Maximum Tx Output power level, where:

s=sign ( + / - )

xx.x = Tx Output power level, +10.0 and –40.0 dBm.

Example: AMX=-13.4

AMX=

AMX?

AMX*

AMX#

AMX?

AMX=sxx.x

(see Description

of Arguments)

AUPC Nominal

Power Level

ANP=

5 bytes

Command or Query.
Nominal Tx Output power level, where:

s=sign ( + / - )

xx.x = Tx Output power level, +10.0 and –40.0 dBm.

Example: ANP=-13.4

ANP=

ANP?

ANP*

ANP#

ANP?

ANP=sxx.x

(see Description

of Arguments)