Comtech EF Data CDM-760 User Manual

Page 134

Advertising
background image

Front Panel Operation

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

6–48

6.2.3.1.1 (Monitor: Live-Alarms) Unit, Transmit, or Receive

Live Press <ENTER> for Details

Unit:---+---+-------------------

Live Press <ENTER> for Details

Tx: -------

Live Press <ENTER> for Details

Rx: ++-------------

Press ENTER and use the   arrow keys to move across the “-“ and “+” characters. Each

character represents a possible alarm. The “-“ character indicates the element in question is

NOT in alarm. The “+” symbol indicates the element is in an alarm (fault) state.

Possible alarms are as follows:

Type

Alarm

State

Unit

MainPs X.X

Main Board Power Supply Fault

(3.3V, 1.5V, 1.2V, 1.8V, 1.0V, 2.5V, 1.25V)

MdmBdPs X.X

Modem Board Power Supply Fault

(5.8V, 3.8V, 2.8V, 3.3V, 1.5V, 1.2V)

Pwr Cal

Transmit power is not factory calibrated. Contact CEFD Product Support.

FPGA Load

An FPGA could not be configured.

Ref Unlock

Unit could not lock to external reference clock input.

Unit Temp

Unit has exceeded operating temperature.

Unit Fault

A general unit fault.

PIIC1 ExtClk Act

A PIIC interface has been selected and the clock is set to lock to an

External Clock (as with G.703 or other Synchronous PIIC cards), however

no clock signal is detected.

PIIC1 ExtClk Out of

Range

A PIIC interface has been selected and the clock is set to lock to an

External Clock (as with G.703 or other Synchronous PIIC cards), however

the clock signal does not match the expected clock rate.

PIIC2 ExtClk Act

A PIIC interface has been selected and the clock is set to lock to an

External Clock (as with G.703 or other Synchronous PIIC cards), however

no clock signal is detected.

PIIC2 ExtClk Out of

Range

A PIIC interface has been selected and the clock is set to lock to an

External Clock (as with G.703 or other Synchronous PIIC cards), however

the clock signal does not match the expected clock rate.

Log File Fault

The file that is used to save all logging data regarding modem parameters

is missing or corrupt.

Int 250 PLL

The modem's internal 250MHz clock out of range or has failed.

Int 900 PLL

The modem's internal 900MHz clock out of range or has failed.

MEO Mdm: Mdm

Comms

The modem has been set to run in MEO mode and the communication

between the remote Tx/Rx modem and remote Rx demod is timing out or is

getting corrupt / unexpected.

MEO Over Air comms

The modem has been set to run in MEO mode and the communication

between the remote Tx/Rx modem and hub / gateway Tx/Rx modem is

timing out or is getting a corrupt / unexpected response.

Advertising