Comtech EF Data CDM-760 User Manual
Page 264

Serial-based Remote Product Management
Revision 2
CDM-760 Advanced High-Speed Trunking Modem
MN-CDM760
8–30
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
PIIC Rx Buffer
Size
RBS =
6 bytes
Command or Query.
Sets or returns Rx Buffer Size (in ms), in the form sxxx.x where:
s = Interface Slot, where:
1 = Slot 1
2 = Slot 2
xxx.x = Rx Buffer Size, in 0.5 ms steps, from 2.0 to 75.0 ms
EXAMPLE: <0/RBS=1032.5 (selects 32.5 ms for Slot 1)
RBS=
RBS?
RBS*
RBS#
RBS?s
RBS=sxxx.x
(see Description of
Arguments)
Re Center
Buffer
RCB = s
1 byte
Command only.
Force the software to recenter the receive buffer.
s = Interface Slot, where:
1 = Slot 1
2 = Slot 2
EXAMPLE: <0/RCB=2 (re-centers the buffer on the Slot 2 interface card)
RCB=
RCB?
RCB#
RCB*
N/A
N/A