Comtech EF Data CDM-760 User Manual
Page 252

Serial-based Remote Product Management
Revision 2
CDM-760 Advanced High-Speed Trunking Modem
MN-CDM760
8–18
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
IP Statistics
N/A
143 bytes
Query only.
Returns all IP Statistics, with each parameter separated by a colon, in the form x.xE+xx for each parameter
is
GBEI1 Parameters
Packets from LAN
Packets to LAN
Bytes from LAN
Bytes to LAN
GBEI2 Parameters
Packets from LAN
Packets to LAN
Bytes from LAN
Bytes to LAN
WAN Parameters
Packets to WAN
Bytes to WAN
Packets from WAN
Bytes from WAN
M&C Parameters
Packets from M&C
Packets to M&C
Optical Parameters
Packets from LAN
Packets to LAN
Bytes from LAN
Bytes to LAN
N/A
ST1?
ST1=(see
Description of
Arguments)