2 (config: tx) data – Comtech EF Data CDM-760 User Manual

Page 95

Advertising
background image

Front Panel Operation

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

6–9

Network

Spec

QPSK

8PSK

16APSK

32APSK

64APSK

DVB-S2-EB2

1/2, 8/15, 17/30,

3/5, 19/30, 2/3,

127/180, 3/4,

4/5, 5/6, 31/36,

8/9, 9/10

17/30, 3/5,

19/30, 2/3,

127/180, 3/4,

4/5, 5/6, 31/36,

8/9, 9/10

19/30, 2/3,

127/180, 3/4,

4/5, 5/6, 31/36,

8/9, 9/10

127/180, 3/4,

4/5, 5/6, 31/36,

8/9, 9/10

4/5, 5/6, 31/36,

8/9, 9/10

ACM

Auto

Auto

Auto

Auto

Auto

(CONFIG: Tx) Mod Frame

You should consider the use of Short Block Framing only when there is a concern

about data latency. In all other circumstances, Normal Block Framing should be used.

See Figure C-4 Single Hop Latency in Appendix G. ADAPTIVE CODING AND

MODULATION (ACM) OPTION for an illustration of how Normal and Short Block

Framing affects overall system latency.

Use the  arrow keys to select Normal (default) or Short Block. Press ENTER.

Note the following:

Setting

FECFRAME Bits Enabled Remarks

Normal

64,800

This is the default (standard) setting.

Short

16,200

Short Block Framing performs 0.2 db to 0.3 db worse in terms of

required Es/No for all ModCods.

(CONFIG: Tx) Mod Pilot

Use the  arrow keys to select Pilots as On or Off, then press ENTER:

•

On enables the insertion of pilot symbols into the physical layer frame

•

Off disables this insertion

When Pilot is On, pilots are always placed at the average power point of any

constellation.

6.2.2.2.2 (CONFIG: Tx) Data

Tx Data Rate Tx Symbol Rate

()

Use the   arrow keys to select Tx Data Rate or Tx Symbol Rate. Press ENTER.