B.2.1.6 t, If i, J6, j7 – Comtech EF Data CSAT-6070 User Manual

Page 99

Advertising
background image

5 to 25 Watt C-Band Transceiver

Revision 0

Redundant Systems

MN/CSAT607025.IOM

Table B-6. M&C Signal Description (Connector J5)

Pin Signal Name

Type

Description

A

RS485 RX+

Pass-thru RS-485 Rx+, From M&C to CSAT A&B

B

RS485 RX-

Pass-thru RS-485 Rx-, From M&C to CSAT A&B

C

RS485 TX+

Pass-thru RS-485 Tx+, To M&C from CSAT A&B

D

RS485 TX-

Pass-thru RS-485 Tx-, To M&C from CSAT A&B

E

B ONLINE CLOSED Output

Shorted to pin K = CSAT B Online

F n.c.

G n.c.

H n.c.

J n.c.

K IND/FLT

COMMON Input

L

A FAULT OPEN

Output

Shorted to pin K = CSAT A Faulted

M

B FAULT OPEN

Output

Shorted to pin K = CSAT B Faulted

N n.c.

P

RED AUTO/MAN

Input

Ground = Manual, Open = Auto

R n.c.

S

A ONLINE CLOSED Output

Shorted to pin K = CSAT A Online

T GROUND

Passive

U GROUND

Passive

V

SWITCH CMD

Input

Momentary short to GND, otherwise OPEN

B.2.1.6 T

X

IF I

NTERFACES

, J6, J7,

AND

J8

The Tx IF input signal is fed from the customers equipment to the RSU-5060 at connector J6.
The RSU-5060 contains a power splitter which feeds the IF input signal to both CSAT A and
CSAT B via the J7 and J8 connectors. The IF power at J7 and J8 will nominally be 3dB less than
the IF input power at J6.

B–5

Advertising