Maintenance and Troubleshooting

41

7. Power up the DM-100 handheld controller.

Note: Do not press any buttons on the DM-100 while displays and controller are booting up.

8. Allow time for DM-100 to boot up and initialize all pylons.

a. About 1 minute for each wirelessly connected pylon

b. About 1 minute total for a direct-wired pylon system

9. On the DM-100, press Menu > Detect Displays to verify all networks and displays are detected.

10. Verify all displays and lines are detected.

11. Manually send the current prices to the display(s) from the DM-100.

12. Verify that the DM-100 states “Sequence Sent” then “Display Response”.

Use the following as a guide for some Point of Sales Systems, I.E. Radiant

1. Verify the ICON on the PoS register does not say, “Price sign is off-line”, if it does, connect the PoS to

the DM-100.

2. Manually send the current prices to the display(s) from the DM-100. (Override the PoS)

3. Press the Update Display button on the DM-100.

4. Verify DM-100 states “Sending Sequence” then “Display Response”.

5. Re-send current prices from PoS system.

6. Verify price change with PoS.

7. The price on the display should change within a minute.

Note: Some states only allow one price change per day. The procedure above allows system
verification without actually changing the display’s price. If allowed, test the entire system by
sending a penny increase to one of the displays and verify change. Return to correct price.

Note: To retain price updates, you must wait 3 minutes before powering down the gas price displays. Any

changes made to the displays require a 3-minute power on time to commit to memory.