CHIPPER ATTACHMENT

Wear Plate Sharpening

The Wear Plate edges become rounded and chipped during use and must be
squared off to ensure efficient operation.

Tools Needed:

Flat File

Straightedge

1. Secure the Wear Plate in a vise.

2. File the edge of the Wear Plate to take out any nicks and to square

rounded edges (Figure 44).

3. Check with a Straightedge to ensure that the Wear Plate edge is flat and

straight.

NOTE: If the Wear Plate is filed enough times that the proper gap between the
Knife and Wear Plate can not be set with the Gap Gauge, you will need to
replace the Wear Plate.

Replacing the Belt

1. Remove the Hand Knob from the top of the Belt Guard and remove the

Guard (Figure 45).

2. Make sure the Belt Release Lever is in the “Release” position (Figure 46).

3. Rotate the Chipper Pulley as you slid the belt from it.

4. Remove the Belt from the Field and Brush Mower Pulley.

Figure 44

Wear
Plate

File this
edge flat

Front View

Side View

Belt Release
Lever

Figure 46

Tighten Belt Position,
Left and Up

Release Belt
Position,
Down and
Right

Figure 45

Hand
Knob

Belt
Guard

Carriage
Bolt
Guides