23

as this ‘CARD SYNC. You can connect two cards using 2 pin sync cable of WaMi Rack 192
Series.

3. SAMPLE RATE

-AUTO: Selecting ‘AUTO’ sets sample rate automatically detected and locked according to the
sample rate of audio source.
-LOCK: In this mode, you can set sample rate manually.

4. INPUT 3,4

Line Input 1,2 of WaMi Rack 192 Series are fixed as analog input channel, but Line Input 3,4
can be switched between analog and digital input channels.
-ANALOG: Selecting this button makes Input 3,4 as analog input and analog source through
Line Input 3 and 4 are routed to input channel
-DIGITAL: Selecting this button makes Input 3,4 as digital input and digital input through
SPDIF Coaxial

5. SPDIF(Digital Type Selector)

-

PRO (IEC 958 Type 1): WaMi Rack 192 Series’s digital in/out format is AES/EBU.

- CONSUMER (IEC 958 Type II): WaMi Rack 192 Series’s digital in/out format is S/PDIF.

6. MONITOR

There are two switches under the MONITOR, which can select monitoring modes
between Stereo and Mono for each pair of input channels.

7. MONIT

When you activate this button, Input signals route to Output 1,2 and you can monitor input
signal in real-time.

8. Input level fader & meter

1. Input 1,2

Under the Monitor select button, this is where to control and see input level of WaMi
Rack 192 Series through Input 1,2 fixed as Analog input channel. You can change the
input level by click and drag the fader and the number at the bottom shows you relative
amount of level in dB, by clicking it you can MUTE the channel.

Advertising
This manual is related to the following products: