Return sensor & pulsation damper assembly, Return sensor and pulsation damper assembly, Forward sensor and pulsation damper assembly – Floscan FloNET Standard Flow Model User Manual

Page 6: Forward sensor & pulsation damper assembly, Installation

Advertising
background image



04/09/2008

2000-081-00

INSTALLATION

MECHANICAL OVERVIEW, (NMEA 2000, K Series Systems)


To Ensure System Accuracy, Follow All Installation Instructions.

Sensor Placement. Determine where the Flow Sensor, or Flow Sensor-Pulsation Damper assembly is to be installed. Install the

sensor, or sensor-pulsation damper assembly so that the two fuel flow arrows, (Î Î) or the, (IN and OUT) markings are on a
horizontal plane. All orientation arrows, (Ï) must be pointing up. The forward sensor or forward sensor-pulsation damper
assembly must be installed downstream of the primary filter. Do not install the sensor or either sensor assembly at a high point in
the fuel system. This could negatively impact system accuracy by trapping air. The fuel return line between the return sensors’
outlet port and fuel tank should be at least 12” long and have a 1 to 2” upward rise. This keeps the return sensor flooded,
improving accuracy. Place sensor assemblies in a protected location away from water spray.

FloScan Instrument Company, Inc.

Tel: (206) 524-6625 Fax: (206) 523-4961

3016 NE Blakeley Street, Seattle, WA 98105 Email: [email protected] Http://www.floscan.com




201/

231-1K

&

2K,

235-2K

201/

231/

235-2K




Determine fitting type & size. Minimize the number of elbows and fittings. If swivel fittings are used, (JIC or SAE) their mating
surfaces must be sealed with Copper Conical Sealing Washer, (Connie Seals) or fitting seals. Fitting seals may be purchased
through Fittings Inc. in Seattle, WA (206) 767-4670, 1-800-552-0632, or a local hydraulic supply house.





233/ 236-1K & 2K

233/ 236-2K

*Caution: Diesel System Components are not designed for use on Gasoline Fuel Systems.

Return Sensor
And Pulsation
Damper Assembly

FloScan

Outlet

Inlet

FloScan

Forward Sensor
And Pulsation
Damper Assembly

Inlet

Outlet

FloScan

FloScan

Forward Sensor &

Pulsation Damper

Assembly

Inlet

Outlet

FloScan

Return Sensor &

Pulsation Damper

Assembly

Inlet

Outlet

Advertising