Vise, Mechanical assembly – Floscan FloNET Standard Flow Model User Manual

Page 8

Advertising
background image



06/02/2011

4001-443-00B

MECHANICAL ASSEMBLY

Standard Flow Diesel Systems (BOS, 201, 231 & 235-2K)


Forward Sensor to Forward Pulsation Damper Assembly


1. Clamp the Pulsation Damper’s aluminum base into a vise.

FloScan

VISE

Hex Flow
Straightener

Sensor
Body

Hex Reducer
Nipple

Pulsation
Damper
Base

2. Coat the Hex Reducer Nipple’s ½” MNPT threads with

sealant.

3. Place the ½” MNPT Hex Reducer Nipple threads into the

Pulsation Damper’s base end with the Inward Pointing
Arrow (Î).

4. Tighten hand tight.

5. Coat the Hex Reducer Nipple’s ¼” MNPT threads with

sealant.

6. Place the Forward Sensor’s “OUT” port onto the ¼”MNPT

Hex Reducer Nipple end.

7. Tighten hand tight.

8. Use an adjustable wrench to tighten the Hex Reducer Nipple

into the Pulsation Damper base.

9. Use an adjustable wrench to tighten the sensor body onto the

Hex Reducer Nipple. DO NOT put a wrench on the Forward
Sensor’s Hex Flow Straightener, at the Sensor’s inlet port

10. When tightened, the Sensor’s base and the Pulsation

Damper base must be even.

CAUTION: When tightening the Forward Sensor onto the Hex Reducer, always place the wrench onto the Sensor’s body.

Never place a wrench on the Forward Sensor’s Hex Flow Straightener while assembling the Sensor onto the Forward

Pulsation Damper. The Flow Straightener is locked into place with a very strong retaining compound and must remain in
position. It must not be tightened or loosened. Moving the Flow Straightener in relation to the Sensor body will destroy the
Sensors accuracy. Turned Flow Straighteners are not considered warranty items.



CAUTION, DO NOT OVER TIGHTEN FLOW SENSOR FITTINGS. Over-tightening may crack the sensor’s body. Cracks
cause leaks, and fuel leaks sometimes cause catastrophic explosions and fire.
Assemble fittings with a Lubricating, Fuel Proof,
Non or Semi Hardening pipe thread sealant, designed for aluminum and stainless steel threads, (Loctite 567 or equivalent).

DO NOT USE TEFLON TAPE.


(Continued on next page)

FloScan Instrument Company, Inc.

Tel:

(206)

524-6625

Fax:

(206)

523-4961

3016 NE Blakeley Street, Seattle, WA 98105

Email:

[email protected]

Http://www.floscan.com

Advertising