2 transport and storage, 1 consignment receipt and unpacking, 2 handling – Flowserve ESP2 User Manual

Page 9: 3 lifting

Advertising
background image

ESP2 USER INSTRUCTIONS ENGLISH PCN-(71569292) 4-12

Page 9 of 64

2 TRANSPORT AND STORAGE

2.1 Consignment receipt and unpacking

Immediately after receipt of the equipment it must be
checked against the delivery/shipping documents for
its completeness and that there has been no
damage in transportation. Any shortage and/or
damage must be reported immediately to Flowserve
Pump Division and must be received in writing within
ten days of receipt of the equipment. Later claims
cannot be accepted.

Check any crate, boxes or wrappings for any
accessories or spare parts that may be packed
separately with the equipment or attached to pallet,
box, or equipment.

Each product has a unique serial number. Check
that this number corresponds with the order. Always
quote this number in correspondence as well as
when ordering spare parts or further accessories.

2.2 Handling

Boxes, crates, pallets or cartons may be unloaded
using fork lift vehicles or slings dependent on their
size and construction. The unit should be stored in a
level position with no strains applied.

2.3 Lifting

Pumps and motors often have

integral lifting lugs or eye bolts. These are intended
for use in only lifting the individual piece of
equipment.

Do not use eye bolts or cast-in lifting

lugs to lift pump, motor and baseplate assemblies.

Care must be taken to lift components

or assemblies above the center of gravity to prevent
the unit from flipping. This is especially true with
In-Line pumps.

Carefully sling ESP pumps so that

bearing lubrication lines (3840.1) will not be bent or
damaged when lifting.

It is advisable to raise the pump into the vertical
position before uncrating. If this isn't possible, pumps
over eight feet long must be supported at more than
one place when raising to the vertical position. Use a
support strap around the bottom column (1341.2)
and on the motor support (3160).

Pump Weights

ESP2

Base Pump

Kg (lb) per 0.15m

(6 in.)

Pump Size

Wt. Kg (lb)

Extra Length

Group 1

1.5x1x6

136 (300)

3.6 (8)

3x1.5x6

139 (305)

3.6 (8)

3x2x6K

145 (320)

4.1 (9)

1.5x1x8

148 (325)

3.6 (8)

3x1.5x8

150 (330)

3.6 (8)

3x2x8

152 (335)

4.1 (9)

Group 2

3x1.5x8

182 (400)

6.8 (15)

3x2x8

184 (405)

7.3 (16)

4x3x8

223 (490)

7.7 (17)

4x3x8L

223 (490)

7.7 (17)

2x1x10

182 (400)

6.8 (15)

3x1.5x10

223 (490)

6.8 (15)

3x2x10

232 (510)

7.3 (16)

4x3x10

286 (630)

7.7 (17)

4x3x10L

309 (680)

7.7 (17)

6x4x10

323 (710)

8.6 (19)

3x1.5x13

259 (570)

6.8 (15)

3x2x13

264 (580)

7.3 (16)

4x3x13

302 (665)

7.7 (17)

Group 3

6x4x13

407 (895)

11.4 (25)

8x6x13

545 (1200)

15 (33)

10x8x13

616 (1355)

16.4 (36)

8x6x15

561 (1235)

15 (33)

10x8x15

645 (1420)

16.4 (36)

Base pump lengths are 0.61m (2 ft.) for

Group 1 & Group 2 pumps and 0.91m (3 ft.) for Group
3 pumps.

On pumps equipped with grease lubricated

shaft bearings, (3020.1 and 3020.2) take care not to
flush the grease from the bearings.

Advertising