4 performance and operating limits – Flowserve MF User Manual

Page 14

Advertising
background image

MF USER INSTRUCTIONS ENGLISH 71569191 12/04

Page 14 of 50

®

Always place two rings of packing below the seal

cage and the remaining rings above the seal cage.

The number of packing rings used is listed in table

6.1.8.1.

PUMP SHAFT

STUFFING BOX

HEAD

IMPELLER

PACKING GLAND

SEAL WATER

CONNECTION

SEAL CAGE

SHAFT SLEEVE

PACKING

Typical gland arrangement

The stuffing box is not packed when

the pump is shipped.

A water supply of approximately 0.113 to 0.227 m

3

/h

(0.5 to 1.0 gpm) is to be introduced to the seal water

connection to provide for packing lubrication and

sealing. A steady "trickle" of water from the stuffing

box will indicate proper adjustment. The sealing

water supply pressure should be 0.35 to 0.69 bar (5

to 10 psi) above the pump discharge pressure.

When grease sealing is used, a similar grease

pressure should be maintained. A slight leakage of

liquid from the stuffing box is to be expected and the

gland

MUST NOT

be tightened to the point of

stopping the leakage.

3.3.7 Shaft seal

The mechanical seal(s) attached to the pump shaft,

seals the pumped liquid from the environment.

Gland packing may be fitted as an option. See

section 6.1.9 for mechanical seal maintenance

information.

3.3.8 Driver

The driver is normally an electric motor. Different

drive configurations may be fitted such as internal

combustion engines, turbines, hydraulic motors etc

driving via couplings, belts, gearboxes, drive shafts

etc.

Fully flexible

couplings are normally used for

connecting pump and drive shafts. For operating

instructions, refer to the coupling manufacturer's User

Instructions.

3.3.9 Couplings

Flexible couplings are normally used for connecting

pump and drive shafts. Many variations of make and

models are available. These couplings provide

compensation for angular and parallel misalignment.

For coupling installation, operating and maintenance

refer to the coupling manufacturer's User

Instructions.

3.3.10 Accessories

Accessories may be fitted when specified by the

customer.

3.4 Performance and operating limits

This product has been selected to meet the

specifications of your purchase order. See section 1.5.

The following data is included as additional

information to help with your installation. It is typical,

and factors such as temperature, materials, and seal

type may influence this data. If required, a definitive

statement for your particular application can be

obtained from Flowserve.

3.4.1 Operating limits

Pumped liquid temperature

limits

*

5 ºC (40 ºF) to +80 ºC (176 ºF)

Maximum ambient

temperature

*

5 ºC (40 ºF) to +40 ºC (104 ºF)

Maximum pump speed

refer to the nameplate

*Subject to written agreement from Flowserve. Special designs

and materials may be available for pumps operating above and

below these specified limits. Contact Flowserve for upgrade

options available for your specific application.

3.4.2 Pump and impeller data

Details such as impeller diameter, wearing ring

diameter are normally provided along with the test

curves. If not provided with the pump

documentation, please contact Flowserve.

Advertising
This manual is related to the following products:

MFC, MFV, MN