Flowserve MF User Manual

Page 25

Advertising
background image

MF USER INSTRUCTIONS ENGLISH 71569191 12/04

Page 25 of 50

®

The grease flowing out of the bearing

frame may be hot and under pressure. Bearings may

run slightly hot immediately after adding new grease.

Monitor the bearing temperatures until they return to

normal. Any marked increase in the temperature of

the bearings after return to normal operation may

indicate the presence of dirt in the bearing,

insufficient cleaning, improper re-assembly, or a

faulty/damaged bearing. In this case the pump

should be immediately stopped and the cause of the

trouble investigated.

5.2.4 Bearing operating temperatures

The maximum operating temperatures for anti-friction

bearings will differ from unit to unit. In general,

bearing frames 3A, 4A and 5A bearings can run up to

16

o

C (60

o

F) and 4T,5T, 6A and 7A sizes can run up

to 38

o

C (100

o

F) above ambient. This should be no

cause for alarm. However, continuously rising

temperatures, or an abrupt temperature rise, are

indicative of possible trouble.

These symptoms require immediate stopping of the

pump and a thorough investigation to determine the

cause of the trouble.

5.2.5 Selection of oil lubricants

The bearings are to be lubricated with a premium

quality paraffinic based turbine or R&O lubricating oil.

The oil should have an ISO 68 Grade, an

approximate Viscosity Index (VI) of 100, a pour point

of -30

o

C (-22

o

F), and a Timken OK load rating of

16kg (35 lbs) minimum. The oil should shed water

and contain oxidation, rust, and foam inhibitors. The

following oils are acceptable. Others oils meeting the

above requirements may also be used.

5.2.5.1 Recommended oil lubricants

AMOCO

Amokon 68 / American Industrial Oil 68

CHEVRON

Turbine Oil GST 68 / Machine Oil R&O 68

EXXON

Terrestic 68

SHELL

Turbo T 68

TEXACO

Regal R&O 68

BP

Turbinol Select-68

5.2.5.2 Recommended oil fill quantities

Fr.

No

Initial

Fill Vol.

m

3

(fl·oz.)

Oil Level

mm

(in.)

±3 mm (±0.125 in.)

3A

0.0004
(13)

N/A-Built with constant level oiler.

4A

0.0006
(22)

N/A-Built with constant level oiler

5A

0.0009
(30)

N/A-Built with constant level oiler

6A

0.0016
(55)

61 (2.4)

7A

0.0035
(120)

71(2.8)

The oil level shown in the table above is applicable

to bearing frames equipped with Timken bearings,

which have externally mounted sight glasses and is

the distance from oil level to the pup shaft centerline.

5.2.6 Recommended grease lubricants

The bearings are to be lubricated with a premium

quality Lithium based NGLI # 2 grease suitable for

anti-friction bearings use. The grease should have a

viscosity range of 150 to 220 cSt (mm

2

/sec) at 40

o

C

(100

o

F) and Timken load rating of 16 kg (35 lb.)

minimum. The grease should contain rust and

oxidation inhibitors and extreme pressure additives.

See table 5.2.6.1 for recommended grease types.

Equivalents may also be used.

5.2.6.1 Recommended grease lubricants

AMOCO

Amolith EP2

CHEVRON

Duralith EP2

EXXON

Lidok EP2

MOBIL

Mobilux EP2

SHELL

Alvania EP2

TEXACO

Multifak EP2

BP

Energrease LS EP 2

Advertising
This manual is related to the following products:

MFC, MFV, MN