Flowserve MF User Manual

Page 24

Advertising
background image

MF USER INSTRUCTIONS ENGLISH 71569191 12/04

Page 24 of 50

®

5.2.2.1 Bearing housing showing oil fill/vent and oil level checker (typical)

This is a STATIC oil level and the oil level will drop during operation; verify that the vent plug is

properly installed so that a false level is not realized.

BEARING

LOCKWASHER

LOCKWASHER

LOCKNUT

THRUST

BEARING

OIL FILL/VENT

SHIM

LINE BEARING

OIL THROWER

SEAL

SHAFT

SEAL

THRUST

BEARING

COVER

BEARING

FRAME

LEVEL

CHECK

LINE

BEARING

COVER

STUFFING

BOX HEAD

OIL

VENT CAP

OIL FILL

SIGHT GAUGE

OIL LEVEL

OIL DRAIN

PLUG

PUMP SHAFT

OIL LEVEL

5.2.3 Bearings–grease lubricated

MF pumps are normally furnished with grease lubricated bearings. Grease fittings are provided on the line and

thrust bearing ends of the bearing housing; see detail below. Before starting the pump, check the bearing

frame cavities for grease and add grease as necessary. For suggested frequency and grease quantity for re-

lubrication, refer to section 5.2.6.2

Proper grease lubrication is very important. Anti-friction bearings can be over-greased as well as under-

greased. After start up, remove the grease fittings or pipe plug closest to the cover and allow the excess

grease to flow out.

5.2.3.1 Grease fittings location on 4T,5T and 7A bearing frames

BEARING FRAME

PLUGGED

GREASE ADDITION

LINE BEARING

PLUGGED

GREASE ADDITION

THRUST BEARING

LINE BEARING END

THRUST BEARING END

Advertising
This manual is related to the following products:

MFC, MFV, MN