Flowserve MF User Manual

Page 39

Advertising
background image

MF USER INSTRUCTIONS ENGLISH 71569191 12/04

Page 39 of 50

®

6.2.2 Service parts

The severity of the condition of service, the extent to

which repairs can be carried out in the field, and the

number of units installed will determine, to a great

extent, the minimum number of service parts that

should be carried in stock at the installation site. It is

suggested, as insurance against delays, that service

parts be purchased at the time the pump order is

placed or as soon after receiving the pump as

possible.

A suggested spare parts list (priced if desired) can be

furnished upon request.

6.2.3 Returning parts

All material returned to the factory must have a

returned material (RM) tag attached. Consult the

nearest Flowserve sales office or OEM factory for

shipping instructions and "RM" tags. Unnecessary

delays are avoided when parts or equipment are

returned to the proper factory using the correct

procedure.

a) When contacting the sales office or factory for

return authorization, list the material to be

returned and the reasons for returning it.

b) On receipt of the "RM" tags, be sure to check the

part name, the part number, the quantity of parts

involved, and the serial number of the equipment.

c)

The "RM" tag must accompany the material

shipped. Enclose it in the shipping container or
attach it to the part being returned

.

d) In cases where more than one part or box is

returned, individually print or stencil your name,

the part name, and the "RM" tag number on each

part or box. Then attach the "RM" tag to one of

the parts or boxes. This will facilitate quick

identification.

Articles being returned should be carefully packed to

prevent damage from handling or from exposure to

the weather.

6.2.4 Storage of spares

Spares should be stored in a clean dry area away

from vibration. Inspection and re-treatment of

metallic surfaces (if necessary) with preservative is

recommended at every six-months.

6.3 Suggested spares and consumable

items

For start up purposes

:

1 - complete set of gland packing

1 - shaft sleeve

1 - set of gaskets and seal kit

(optional: 2 - mechanical seal kits)

For 2 years operation

:

1 - set of bearings (line and thrust)

2 - sets of gland packing

2 - shaft sleeves

2 - sets of gaskets and seal kits

2 - lantern rings

2 - casing wear rings

(optional: 2 - mechanical seal kits

2 - impeller wear rings)

For 4 years operation

:

1 - set of bearings (line and thrust)

2 - sets of gland packing

2 - shaft sleeves

2 - sets of gaskets and seals

2 - lantern rings

2 - casing wear rings

1 - impeller

(Optional: 2 - mechanical seal kits

2 - impeller wear rings)

6.4 Tools required

No special tools are required to maintain these

pumps. In general, most tools are readily available in

standard tool kits, and dependent on pump size

:

Open ended spanners (wrenches)

Socket spanners (wrenches)

Allen keys

Range of screwdrivers

Soft mallet

More specialized equipment

:

Bearing induction heater/Oven

Dial test indicator

C-spanner (wrench) - for removing shaft nut.

(If difficulties in sourcing are encountered,

consult Flowserve).

Advertising
This manual is related to the following products:

MFC, MFV, MN