5 supported hart commands, 1 universal commands, Figure 3.2 – device variable units – Flowserve MX HART Field Unit User Manual

Page 22: Table 3.7 – hart universal commands

Advertising
background image

MX/QX HART Field Unit FCD LMENIM2340-00 – 1/14

22

Figure 3.2 – Device Variable Units

3.5 Supported HART Commands

The following Universal and Common HART commands are supported by the Limitorque MX/QX HART device. See
Appendix B for more information on HART data formats such as: Packed, Latin-1, Date and Time. See Appendix C for
more information on “Enum” or “Bits” formats. See Appendix E for more information on valid Response Codes for each
command.

3.5.1 Universal Commands

Table 3.7 – HART Universal Commands

Command

Request Data Bytes

Response Data Bytes

No.

Description

Byte

Format

Description

Byte

Format

Description

0

Read Unique

Identifier

0

1-2

3

4

5

6

7

7

8

9-11

12

13

14-15

16

17-18

19-20

21

Unsigned-8

Enum

Unsigned-8

Unsigned-8

Unsigned-8

Unsigned-8

Unsigned-5

Enum

Bits

Unsigned-24

Unsigned-8

Unsigned-8

Unsigned-16

Bits

Enum

Enum

Enum

254”

Expanded Device Type = 0x3008

Min. number of request preambles = 5

HART Protocol Major Rev. = 7

Device Rev. Level

Software Rev. Level

(5 MSB) Hardware Rev. Level

(3 LSB) Physical Signaling Code=0

Device Flag Assignment = 1

Device ID (unique for given device type)

Min. number of response preambles=5

Max. number of device variables = 5

Configuration Change Counter

Extended Field Device Status: 0=OK,

1=Maintenance req’d, 2=Device Alert

Manufacturer Identification Code = 0x0030

Private Label Distributor Code = 0x0030

Device Profile = 1

1

Read Primary

Variable

0

1-4

Enum

Float

Primary Variable Units = 57 (%)

Primary Variable

2

Read Loop

Current And

Percent Of

Range

0-3

4-7

Float

Float

Primary Variable Loop Current (mA)

Primary Variable % Of Range

3

Read Dynamic

Variables And

Loop Current

0-3

4

5-8

9

10-13

14

15-18

19

20-23

Float

Enum

Float

Enum

Float

Enum

Float

Enum

Float

Primary Variable Loop Current (mA)

Primary Variable Unit Code

Primary Variable

Secondary Variable Unit Code

Secondary Variable

Tertiary Variable Units Code

Tertiary Variable

Quaternary Variable Unit Code

Quaternary Variable

6

Write Polling

Address

0

1

Unsigned-8

Enum

Polling Address of Device

Loop Current Mode

0

1

Unsigned-8

Enum

Polling Address of Device (0-63)

Loop Current Mode

7

Read Loop

Configuration

0

1

Unsigned-8

Enum

Polling Address of Device (0-63)

Loop Current Mode

Advertising