Flowserve MX HART Field Unit User Manual

Page 70

Advertising
background image

MX/QX HART Field Unit FCD LMENIM2340-00 – 1/14

70

Command

Response Code

No.

Description

Code

Class

Description

106

Flush Delayed Responses

0

1-5

6

7

8

9-15

16

17-31

32

33-127

Success

N/A

Error

N/A

Warning

N/A

Error

N/A

Error

N/A

No Command-Specific Errors

Undefined

Device-Specific Command Error

Undefined

All but running delayed responses flushed

Undefined

Access Restricted

Undefined

Busy

Undefined

107

Write Burst Device Variables

0

1

2

3-4

5

6

7

8

9

10-15

16

17-127

Success

N/A

Error

N/A

Error

Error

Error

Warning

Error

N/A

Error

N/A

No Command-Specific Errors

Undefined

Invalid Selection

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

In Write Protect Mode

Burst Condition Conflict

Invalid Burst Message

Undefined

Access Restricted

Undefined

108

Write Burst Mode Command

Number

0

1

2

3-4

5

6

7

8

9

10-15

16

17-127

Success

N/A

Error

N/A

Error

Error

Error

Warning

Error

N/A

Error

N/A

No Command-Specific Errors

Undefined

Invalid Selection

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

In Write Protect Mode

Burst Condition Conflict

Invalid Burst Message

Undefined

Access Restricted

Undefined

109

Burst Mode Control

0

1

2

3-4

5

6

7

8

9

10-15

16

17-31

32

33

34

35

36

37-127

Success

N/A

Error

N/A

Error

Error

Error

Warning

Error

N/A

Error

N/A

Error

Error

Error

Error

Error

N/A

No Command-Specific Errors

Undefined

Invalid Selection

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

In Write Protect Mode

Update Period Increased (some bandwidth available)

No bandwidth available

Undefined

Access Restricted

Undefined

Busy

DR Initiated

DR Running

DR Dead

DR Conflict

Undefined

115

Read Event Notification

Summary

0

1

2

3-4

5

6

7-127

Success

N/A

Error

N/A

Error

Error

N/A

No Command-Specific Errors

Undefined

Invalid Selection

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

Undefined

116

Write Event Notification Bit Mask

0

1

2

3-4

5

6

7

8-15

16

17-127

Success

N/A

Error

N/A

Error

Error

Error

N/A

Error

N/A

No Command-Specific Errors

Undefined

Invalid Selection

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

In Write Protect Mode

Undefined

Access Restricted

Undefined

117

Write Event Notification Timing

0

1-4

5

6

7

8

9

10-15

16

17-31

32

33

34

35

36

37-127

Success

N/A

Error

Error

Error

Warning

Error

N/A

Error

N/A

Error

Error

Error

Error

Error

N/A

No Command-Specific Errors

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

In Write Protect Mode

Update Period or De-bounce Interval Adjusted

Invalid Event Specification number

Undefined

Access Restricted

Undefined

Busy

DR Initiated

DR Running

DR Dead

DR Conflict

Undefined

Advertising