Close the side cover.

7.

Press the [Reset] button to reset the error and restart the job.

FlexFeed

When a stoppage occurs in the flexFeed, remove the documents from the flexFeed as
follows:

1.

Open the top cover A by pulling up the handle.

2.

Remove the documents from the flexFeed area.

3.

Close the top cover A.

4.

Press the [Reset] button to reset the error and restart the job.

Collating Area

When a stoppage occurs in the collating area, remove the documents from the collating
area as follows:

1.

Move the collator plate B down.