General

Safety

The charger is fitted with the following protection devices for safe handling:
-

No sparks when clamping onto battery due to de-energised charging terminals

-

Protection against short-circuiting of charging terminals/polarity reversal

-

Protection against thermal overload of the charger

Utilisation in ac-
cordance with
“intended pur-
pose“

The charger is intended exclusively for charging the following types of battery:
-

Lead-acid batteries with liquid electrolyte (Pb, GEL, Ca, Ca silver)
or

-

Lead-acid batteries with fixed electrolyte (AGM, MF, sealant).

IMPORTANT! Charging dry batteries (primary cell) with this charger shall be deemed to
be „not in accordance with the intended purpose“. The manufacturer shall not be liable for
any damage resulting from such improper use.

Symbols used

WARNING! Risk of injury and damage from exposed, rotating vehicle parts.
When working in the vehicle’s engine compartment, take care that hands, hair,
items of clothing and charger leads do not come into contact with moving parts,
e.g. fan belt, fan, etc.

CAUTION! Setting the mode incorrectly can result in product damage and poor
charging performance. Always set the mode according to the type of battery to be
charged.

NOTE! No protection from polarity reversal in the case of a deep-discharge bat-
tery. If the battery voltage is too low (< 1.0 V), the charger cannot detect whether
the battery is connected or not. Before starting charging manually, check that the
charging terminals are connected to the correct poles.

Devices equipped with main switch:
-

Switch off main device switch

-

Unplug device from the mains

Devices with no main switch
-

Unplug device from the mains

Devices equipped with main switch:
-

Connect device to the mains

-

Switch on device main switch

Devices with no main switch:
-

Connect device to the mains