main charging voltage (user charging)
setting range: 12.0 - 15.5 V, in steps of 0.1 V

conservation charging voltage (user charging)
setting range: Off / 12.0 - 15.5 V, in steps of 0.1 V

IMPORTANT! Conservation charging does not take place if conservation charging is set
to OFF. However, if the battery voltage drops below 12 V, charging starts.

safety cut-out (user charging)
setting range: 2 h - 30 h, in 10 min intervals

IMPORTANT! If charging does not end automatically after the set time has elapsed, the
charger will be switched off as a safety precaution..

maximum external power supply
Setting range: see Technical Data, in steps of 0.5 A

external power supply voltage
setting range: 12.0 - 15.5 V, in steps of 0.1 V

refresh charging voltage
setting range: 12.0 - 17.0 V, in steps of 0.1 V

refresh charging period
setting range: 2 h - 30 h, in 10 min intervals