5.

3.

1.

MOUNT CHASSIS ASSEMBLY TO WALL AS
SHOWN IN FIGURE 14.

ENSURE AT LEAST 3" OF BLOCKING MATERIAL
BEYOND BOTH UPPER AND LOWER EDGES OF
CUT-OUT.

CUT A 9-1/2" x 12-1/2" OPENING IN WALL
CENTERED BETWEEN THE STUDS.

WB-X1 INSTALLATION (OLD-WORK)

4.

2.

STEPS:

INSTALL OLD-WORK MOUNTING BRACKET TO
CHASSIS ASSEMBLY AS SHOWN IN FIGURE 13.

INSTALL SCREW/CLAMP BLOCK ALONG EDGE OF
CUT-OUT AS SHOWN IN FIGURE 12 - SEE STEP 3.

1" CUSTOMER-SUPPLIED
BLOCKING - 5/4 WOOD
MATERIAL RECOMMENDED

2 x 4 STUDS
16" ON CENTER

SCREW/CLAMP BLOCK

(8) CUSTOMER-

SUPPLIED

#8 WOOD SCREW

1/2" OR 5/8" DRYWALL

CHASSIS ASSEMBLY
(AVAILABLE WITHOUT KO'S)

(2) OLD-WORK
MOUNTING
BRACKET

(8) #8-32 SCREW

(SUPPLIED)

FIGURE 12

FIGURE 13

FIGURE 14

(8) CUSTOMER-SUPPLIED
#8 WOOD SCREW
(AFTER CHASSIS IS IN
POSITION IN WALL)