Installing the Commercial Atlas (9800K) ATC Kits
Page 22
MDE-4431C Gasboy ATC M05819K00X Kits Installation Manual · February 2013
12
), disconnect the Connector connected to the Pulser 1,
Handles, and Pulser 2 jacks.
Figure 15: CPU PCB Assembly
Pulser 1 and
Handles Jacks
Pulser 2 Jack
LCD Display
Jack
LCD Display
Jack
Pulser 1 and
Handles Jacks
Pulser 2 Jack
(i)
(ii)
CPU PCB Assembly with Connections
CPU PCB Assembly without Connections
13
Locate the Circuit Board Assembly (461A2) provided in the kit (for identification, see
). Connect the assembly to the jacks labeled Pulser 1, Handles, and Pulser 2
at the CPU PCA.
14
Reconnect the Connector removed in step
on
to the Circuit Board Assembly [461A2