Gasboy Vapor Recovery Kit User Manual

Gasboy Hardware

Advertising
background image

032627 Rev. 0096

Page 1

VAPOR RECOVERY KIT INSTALLATION INSTRUCTIONS

FOR MODEL 9120

This instruction sheet covers the installation of the Model 9120, Vapor Recovery Kit (P/N 032628). Vapor recovery kit
does not include high hose retriever, hose, nozzle, swivel, and breakaway). You should have received the following:

Item

Qty.

P/N

Description

1

1

042741

Discharge Assembly

2

1

041605

Panel, Right Side (VR)

3

1

028934

Grommet

4

1

003317

Boot, Nozzle (VR)

5

2

052857

Bolt 8-32 x 5/8

6

1

003719

Hook, Nozzle (VR)

Item

Qty.

P/N

Description

7

1

049013

O-Ring

8

2

051805

Bolt 1/4-20 x 5/8

9

2

068891

Washer-Lock ¼

N/A

1

032627

Instruction Sheet

N/A

1

035282

Warning Sheet

Important: Read all instructions before beginning installation. Also, read and follow all precautions
regarding remote dispensers and pumps on the Warnings and Safeguards
sheet, 035282, included in this
kit. Before performing any work which may produce sparks (e.g. drilling, use of power tools, etc.), remove
dispenser a safe distance from any flammable materials.

Installing Right Side Panel

1.

Remove front door panel (key required).

2.

Remove bezel assembly by unfastening two (2) Phillips head screws.

3.

Remove rear door panel (key required).

4.

Remove three (3) Phillips head screws and remove rear access panel.

5.

Remove discharge pipe elbow.

6.

Remove six (6) nuts from top cover assembly and remove top cover.

7.

Remove three (3) screws from right side panel. Remove right side panel and discard.

8.

Assemble new right side panel (item 2) with three (3) screws from Step 7.


Installing Discharge Assembly

9.

Remove two (2) 5/16-18 bolts from discharge casting
and two (2) 1/4-20 bolts from discharge clamp.
Remove discharge assembly from unit. NOTE:
Replace O-ring with supplied (item 7) O-ring. Apply
lithium based grease to O-ring.

10. Install new vapor recovery discharge assembly by

reinstalling two (2) 5/16-18 bolts and two (2) 1/4-20
bolts from Step 9. NOTE: 1/4-20 bolts will secure
vapor recovery bracket to platform assembly.

11. Remove two (2) 8-32 screws from nozzle boot

casting and remove. Install vapor recovery nozzle
boot (item 4) with same screws.

12. Remove two (2) 1/4-20 bolts from nozzle hook

assembly and remove nozzle hook. Install vapor
recovery nozzle hook (item 6) with same 1/4-20
bolts.

13. Reinstall the dispenser top cover and panels by

following Steps 6 through 1.