Gasboy CFN Islander I User Manual

Cfn islanderi & ii installation quotation guide, Hardware description

Advertising
background image

CFN IslanderI & II

Installation

Quotation

Guide

(For Quotation Use Only - Do Not Install From This Guide)


This document is provided as a guide for quoting the installation of a CFN Islander system. Component location, power, wiring, and
conduit requirements can be calculated from this guide. The CFN Islander Installation Manual (not this guide!) should be used for the
actual installation of the system. GASBOY will not be responsible for installations performed from this guide.

HARDWARE DESCRIPTION


The GASBOY CFN Islander systems are microprocessor-based
automated fueling systems that control electronic or mechanical
pumps or dispensers. The CFN systems are made up of modular
components so you can custom-tailor the system to your needs.


Depending on your application, you could have several or all of
the following components:

Islander I or Islander II

CRT Terminal and Printer

Islander Satellite Readers or Satellite Readers with Receipt
Printers

Consoles

Standalone Receipt Printers

Cash Drawers

PIN Pads

Pump Control Units (wall-mount or pedestal)

RS-485 Junction Box(es)

Internal or external phone modems


Standard Islander System Features
Magnetic or optical card or cardless operation. Controls up to
32 hoses. Standard or receipt printer post. Certain applications
require peripheral pump control units: the standard pedestal can
contain two pump control units controlling up to eight hoses;
receipt printer pedestal can contain one pump control unit
controlling up to four hoses. Remote wall-mount pump control
unit(s) can also be used. Display: 2x20-character LCD, backlit,
displays programmable instructional messages. Read Method:
ABA Track II Magnetic, manual swipe; or Static read optical.
4x4 Membrane keypad. Options: DES Encryption of PIN
numbers, receipt printer mounted in pedestal or pump control
unit mounted in pedestal, disable pumps button. Supports up to
7 satellite readers. Satellite readers contain same features as
Islander, minus CPU and memory boards.


Islander I Features
Site Controller I with 512K memory is designed for fuel-only
operations where access to financial networks is not required.
Two asynchronous RS-232 or RS-422 ports for terminal and/or
computer communications (Local port-CRT/logger printer;
remote port-modem/computer/terminal). Two RS-485 ports for
communications with other CFN devices at the fueling site.


Islander II Features
Site Controller II with 608K battery-backed RAM is designed
for fuel and merchandise operations and controls/interacts with
all your automated fueling equipment including pump control
devices and satellite Islander readers. Two PCMCIA card slots
and two PCMCIA SRAM cards for mass storage of data and
operating system program loading. Ports: Four asynchronous
RS232 or RS422 (0-data terminal/logger; 2-modem/computer; 1
and 3 individually configurable). Two RS-485 ports for
communications with other CFN devices at the fueling site.
Various network interfaces may require a modem. Dispenser
interfaces: GASBOY, Gilbarco*, Tokheim*, Wayne, Bennett,
Tokheim DPT, Wayne CAT*, Gilbarco CRIND*,
Unidynamics*, LTS* (propane).
* Requires interface equipment.