Credit & Debit Card Networks

Amoco/DataCard 001

3

Gasboy CFN Series

system command files. You may have Shift.fmt and Day.fmt from the BIN directory of
the C drive, Offroad.DTA if used and the Prntsys.dta for reference.

If Offroad.dta is used by the site, you may need to modify the products used by that

file due to the new Amoco fuel products or necessary movement of merchandise
products.

You may also wish to copy the files that contain the customer’s current shift reports

for reference. For the original report package, these files are located in the root
directory of the CL drive labeled as SHIFT.x. For the New Shift Report package, the
reports are located in the REPORTS directory. These reports may be reprinted but not
regenerated.

7.

Insert the NEW Amoco Application Disk in the A: drive.

8.

Type A:/BIN/Install

9.

Respond with N if asked to copy SYSBACK.DTA and OFFROAD.DTA

10. At the “Do you want to install from an additional floppy disk (Y/N)” insert the new

Amoco Release Disk, type Y and press enter.

11. Copy the Amoco.dta file to the C: drive.
12. Copy the Datacard.bin file into the C:/BIN directory.
13. Copy the backup files into their respective directories.
14. Type REBOOT;A at the C prompt. This will load the new operating system.
15. Go to number 6 in setting up a new site to load settings.

For a new site:

1.

Run AMINSTAL.CMD to copy the files onto the hard disk.

2.

From the command line, run FIX TR;I

3.

Then REBOOT;A to load the new operating system and configuration.

4.

Run AMRESTOR.CMD to restore the Amoco specific ICR messages and fuel
products.

5.

Run DATACARD.BIN to set up the router table.

6.

Set up the tank table using the LOAD TANK command.

7.

Set up the fuels using the LOAD FUEL command.

8.

Set up pump configuration using the PUMP program.

9.

Type SYSBACK and then REBOOT.

10. Set the Site Controller CPU board K2 jumper “to DTE” as shown in the diagram on

page 7.

Once the Site Controller has been configured, run reboot to load the new configuration.

After the DataCard 780 unit has been set up and has dialed in and received its download from
the Amoco host, connect the DataCard 780 unit (9 pin connector) to Port 3 (25 pin connector) on
the Site Controller using interface cable C07162. When the DataCard unit establishes
communication with the Site Controller the remainder of the configuration information will be
downloaded from the DataCard unit to the Site Controller (receipt configuration, fuel prices, and
system time). If the download does not occur automatically, execute the reboot command to
force the DataCard 780 unit to send the configuration and price information.

Note: The Data Card system must use the same power source as the other Gasboy equipment.