Rs-232 character framing, Print transaction, Site-host mode – Gasboy CFN III Quick Reference Guide v3.3 User Manual

Page 60

Advertising
background image

CFN III Quick Reference

Page 56

MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005

CFN3 to Modem

For CFN3 to modem use part number C05995.

CFN3 to Okidata

For CFN3 to Okidata use part number C05994.

RS-232 Character

Framing

ASCII, 8 data bits, no parity, 1 stop bit.

Print Transaction

Host-Site Mode

Code = PT; options = A
<ENQ>aaPTb<ETB><crc><EOT>
The Site Controller response is:

<STX>aaPTbrrssss0ddddddxyffggggqqqqqqqqooooooo

ppttttyymmddhhnneennnnnnvvvvvvvv
aa...aa,[00..00]tdwkii...iikeeeepppp<ETB><crc><EO
T>

Completed Transaction Codes

Code

Message*

Meaning

7

Refund

transaction is a refund**

8

Return

transaction is a return**

9

Payout

transaction is a payout**

10

Mem Lost

pump control unit’s memory was
lost due to battery failure

40

Pwr Fail

transaction terminated due to a
power failure at the pump
control unit

41

normal transaction

42

Timed Out

transaction timed out at the
pump

43

Limit

pump cut off at limit

45

Reversal

transaction is a reversal

50

Unassigned

a device completed a transaction
but the Site Controller does not
have a record of it.

52

Gate

transaction was started at a gate
controller

54

Aborted

transaction was aborted (p ump
was deactivated) before
pumping was completed

55

Delivery

transaction is a fuel delivery,
either manually entered at the
card reader terminal*** or
registered by a tank monitor

71

Manual

transaction was manually
entered at the card reader
terminal***

77

Pulse err

caused by dual pulser failure

78

Prod out

pump reports it is out of this

type of product

79

Pump down a pump is not working**

81

Withdrawal transaction was a cash

withdrawal**

* The message printed in the Error field of the

transaction printout.

** Site Controller II and III.
*** Site Controller I only

Site-Host Mode

Standard log in—an example of the sign-on
command and response with calculated CRC-16
check sums:
<ENQ>01CK0GASBOY<ETB>E7B6<EOT>
<STX>01CK00085112514080006000600060001002
0 2V010,<ETB>D389<EOT>

Advertising