Service Manual

Voltage Check #3 - Figure 3-7

Check voltage across IGBT module.

Figure 3-7 Voltage Check #3 - Across IGBT Module

230V and 400V

208-240V and 480V

PMX600.24

+

A

B

C

A

B

C

A

160
280
165
330

C

325
565
330
660

B

160
280
165
330

230 VAC
400 VAC

208-240 VAC

480 VAC

Line Voltage