3-26

MAINTENANCE

powermax

600

Service Manual

COMPONENT REPLACEMENT

WARNING

ELECTRIC SHOCK CAN KILL

Disconnect electrical power before performing any maintenance.

See warnings on page 3-6 before proceeding.

Power Cord Replacement

Figure 3-10 Power Cord Replacement

Disconnect electrical power and gas supply before removing the old power cord.

Installation

- See Figure 3-10.

1. Insert the new power cord through the strain relief.
2. Pass all 4 wires through the toroid, as shown (230 and 400 volt only).
3. Install the power cord connections where shown.
4. Tighten the strain relief onto the power cord.
5. Install the power supply cover.
6. Reconnect electrical power and gas supply.

208V - 240V

230V and 400V

PMX600.12

480V

230V

400V

NOTE: Toroid

must be installed for power

supply to be in compliance with
EMC standard EN50199.

BROWN

YELLOW
GREEN

Pass all 4 wires through
the toroid 2 times.

Pass all 4 wires through
the toroid 3 times.

BLUE

BLACK

GREEN

BLACK

WHITE

BLACK

GREEN

WHITE

RED