MAINTENANCE

powermax

600

Service Manual

Removal

Disconnect electrical power.

Disconnect gas supply.

Remove the power supply cover.

Air Filter Element Replacement

Refer to Figure 3-12.

Figure 3-12 Air Filter Element Removal

Unscrew the filter bowl.
Do not discard the O-ring.

Remove the filter element
from the filter housing.

NOTE: Do not allow the filter element
to turn when loosening the screw.

Compress the hose fitting collar and
pull the gas hose from the hose fitting.

Pull the drain hose from the grommet
in the floor of the power supply.