2 scaling formulas, 6 preset value, 1 overview – ifm electronic RN7003 User Manual

Page 16

Advertising
background image

CANopen encoder

16

Format of the singleturn scaling parameters

Byte

3

2

1

0

Bit

31 - 24

23 - 16

15 - 8

7 - 0

Data

2

31

- 2

24

2

23

- 2

16

2

15

- 2

8

2

7

- 2

0

object 6001h - steps per revolution

Format of the multiturn scaling parameters

Byte

3

2

1

0

Bit

31 - 24

23 - 16

15 - 8

7 - 0

Data

2

31

- 2

24

2

23

- 2

16

2

15

- 2

8

2

7

- 2

0

object 6002h - total measuring range in steps

Scaling formulas

6.5.2
The scaling function used in the CANopen encoder is limited to a singleturn

resolution within a step� After the download of new scaling parameters the preset

function should be used to set the start point of the encoder�

Only change the scaling function parameters if the shaft is stationary�

In the following formula a 25-bit multiturn encoder with a singleturn resolution of 13

bits is used as an example�
Formula for the multiturn scaling function:
A = (singleturn_position x steps_per_revolution) / 8192
output_position = (revolution_number x steps_per_revolution) + A
Where: singleturn_position = absolute singleturn position value
revolution_number = absolute multiturn number

Preset value

6.6

Overview

6.6.1
The preset function (object 0x6003h) supports the adaptation of the encoder to the

mechanical zero point or to a preset value� The preset function is used after the

scaling function� The preset value is then provided as a measured value�
A preset value is determined by the encoder as follows:

Advertising
This manual is related to the following products: