1 pdo configuration – ifm electronic RN7003 User Manual

Page 19

Advertising
background image

UK

CANopen encoder

19

The structure of the entries of the object "transmit PDO mapping parameter" in

subindices 1���3 is as follows:

Byte MSB

Byte MSB - 1 Byte LSB + 1

Byte LSB

object

subindex

object length (number of bits)

PDO configuration

6.9.1
To change the PDO mapping the encoder must be in the NMT mode pre-

operational� The PDO must be set to "not valid"� This is done by deleting bit

31 (MSB) in subindex 1 "COB-ID used by PDO" in the object "transmit PDO

communication parameters"�
The PDO "transmit PDO mapping parameter" must be deactivated� To do so, set

the subindex 0 to 0�
To reconfigure the PDO mapping transmit the data of the corresponding object,

the subindex and length of the first object to "transmit PDO mapping parameter"

in subindex 1� Then proceed in the same way for the optional second and third

objects and transmit to "transmit PDO mapping parameter" in subindices 2 and 3�
The "transmit PDO mapping parameter" subindex 0 must be set to the number of

the objects mapped in the PDO (1-3)�
The reconfigured PDO mapping must be set to "valid" by the setting bit 31 (MSB)

in subindex 1 "COB-ID used by PDO" in the object "transmit PDO communication

parameters"� After setting the encoder in the NMT mode operational the

reconfigured PDO mapping is enabled�

The PDO mapping can be stored in the non-volatile EEPROM using the object

0x1010 "store parameter field" (subindex 1 "all parameters" or subindex 2

"communication parameters")�