2 node address, 3 bus termination, 4 baud rate switch – ifm electronic RN7003 User Manual

Page 7

Advertising
background image

UK

CANopen encoder

7

supply +U

6:

B

zero set button

7:

screw terminals for bus and power supply connection

8:

Node address

4.2
The node address of the device can be set via two decimal rotary switches in

the device� The step increment x10 and x1 is specified next to the switches�

The permitted address range is between 3 and 98� The address range 0 to

2 is reserved for the master� Address 0 is used for broadcasting, i�e� master

broadcasting to multiple slaves� Note that each address used in a CANopen

network must be unique and must not be used by other devices�
The device address is read and adopted when the encoder power supply is

switched on (or the NMT command Reset_Communication or Reset_Node)� Both

actions are required to adopt changes to the address settings�

Bus termination

4.3
In a CANopen network all devices are connected in a bus structure� Up to 32

devices (masters and/or slaves) can be connected in one segment� If more

devices are needed, repeaters must be used to amplify the signals between the

segments� An active termination must be added at the beginning and end of each

bus segment to ensure an error-free operation� These terminations are integrated

into the device and can be activated via DIP switches�
The active termination is only activated if the encoder is switched on� If the device

is switched off, the CAN_H and CAN_L lines are internally terminated by a 121 Ω

resistor�

Bit 1

Bit 2

Effect

on

on

121 ohm resistor between CAN_H and CAN_L

on

off

no valid setting

off

on

no valid setting

off

off

no resistor between CAN_H and CAN_L

Baud rate switch

4.4
The communication baud rate can be set using the rotary switch inside the

encoder� The baud rate is set according to the following table�

Advertising