22

Bit

Parameter

1

no indication

2

scaling function control

3���14

no indication

15

read position at SYNC

Operating parameters (object 0x6000)

Diagnosis of the encoder

6.11.1
The diagnosis of the encoder can be read by the objects 65xxh� The operating

status, alarm and warning diagnosis is described in the following chapters� For a

complete overview of the supported diagnosis please refer to the EDS file�

Operating status

6.11.2
In the object 6500h the operating status can be read� The function for each bit

corresponds to the operating parameters, see chapter 6�4�
In the operating status the scaling function control (bit 2) is set depending on the

setting in the operating parameters� In addition, the actual scaling values used in

the encoder can be read as diagnosis, object 6501h (singleturn resolution) and

object 6502h (multiturn resolution)�

Alarms and warnings

6.12
If an internal alarm is detected by the encoder, it automatically passes into the

pre-operational status� A COB-ID EMCY message (object 0x1014h) is transmitted

by the encoder� This message transmits the alarm type occurred� To return to the

operating status an NMT command must be transmitted� The encoder supports the

following alarms�

Bit

Supported alarms

0

position error

1-11
12

E2prom error

13���15

Alarms (object 0x6506/0x6505)

Bit

Supported warnings

0
1

lighting control

2

watchdog